Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 138895.015 - Employee is killed in trench wall collapse

Accident Summary Nr: 138895.015 -- Report ID: 0830500 -- Event Date: 09/07/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1551677.01509/07/2021237110Castillo Excavating, Inc.

Abstract: At 12:08 p.m. on September 7, 2021, an employee worked in a trench to replace an existing sewer line. At some point, the trench wall collapsed and buried the employee, who was killed by asphyxiation.

Keywords: Asphyxiated, Buried, Collapse, Installing, Pipe, Sewer, Trench, Wall
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant Alteration or rehabilitation   8 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1551677.015 87 M Fatality Excavating and loading machine operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close