Accident Summary Nr: 138824.015 - Employee is killed when exposed to hydrogen sulfide

Accident Summary Nr: 138824.015 -- Report ID: 0551800 -- Event Date: 08/27/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1550576.01508/30/20215541447110112277 - Heartland Truck Stop & Wash

Abstract: At 12:00 noon on August 27, 2021, an employee entered a tanker trailer to power wash the interior of the tanker. The tanker had contained animal parts, and was sitting outside in the high summer temperatures. The employee was found unconscious inside the tanker and emergency services were notified. Upon arrival, the fire department detected hydrogen sulfide at twice the level considered to be immediately dangerous to life and health at the open manway on the top of the tanker. No air monitoring had been done prior to entry into the tanker. No attendant was in place and there was no retrieval system set up to enable non-entry recue of the employee from outside the tanker. The employee died due to asphyxiation.

Keywords: Asphyxiated, Chemical Exposure, Cleaning, Confined Space, Hydrogen Sulfide, Inhalation, Lung, Respiratory, Tank, Tractor Trailer, Trailer, Unconsciousness

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1550576.015 27 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close