Accident Summary Nr: 138793.015 - Employee is struck and killed by falling crane boom

Accident Summary Nr: 138793.015 -- Report ID: 0552651 -- Event Date: 08/31/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1551058.01509/01/2021237990Michels Foundation A Division Of Michels Corporation

Abstract: At 11:30 a.m. on August 31, 2021, an employee rigged a bulkhead to be lifted by a crane. At some point, the crane failed, and the boom fell, struck, and killed the employee.

Keywords: Crane, Crane Boom, Equipment Failure, Falling Object, Material Handling, Rigging
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1551058.015 49 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Seawall construction, riprap placement
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.