Accident Summary Nr: 138787.015 - Employee is injured when caught in rotating table while perf

Accident Summary Nr: 138787.015 -- Report ID: 0950635 -- Event Date: 03/15/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1527270.01504/26/2021334511Space Exploration Technologies Corporation

Abstract: At 10:00 a.m. on March 15, 2021, an employee was responding to a repair request for the Honor VL-125C CNC machine, a vertical turning lathe. The employee was working alone. The machine was in manual data input (MDI) mode, and the employee input a M03 "Spindle Forward Set" command instead of the M06 "Auto tool change" command into the control panel of the machine. The key to the interlock had been left in the machine from a previous maintenance of the machine, and it had been turned to the "O" position. The "O" position disabled the interlock function of the door, which normally would cause the machine to turn off. The employee was caught in the rotating table. The employee suffered a torn ligament and lacerations to his left knee and was hospitalized.

Keywords: CNC Routing Machines, Caught In, Interlock, Knee, Laceration, Lathe, Ligament, Maintenance, Repair, Rotating Parts, Tear, Working Alone

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1527270.015 27 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close