Accident Report Detail
Accident Summary Nr: 138608.015 - Employee sustains amputation and crushing injury from moving
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1516433.015 | 02/24/2021 | 326220 | Kakuichi America Inc |
Abstract: At 11:45 a.m. on January 26, 2021, an employee was investigating a sound coming from the Take Up Machine (Machine #0520) in the PVC Section Department. The employee removed a metal guard enclosure to inspect the belt and pulley drive, which was energized and in full operation. Using an L-Wrench, the employee applied pressure to the moving belt, causing the right hand's index and middle fingers to be pulled between the belt and pulley drive. The employee sustained an amputation of the index finger and a crushing injury to the middle finger on the right hand. Emergency services transported the employee to the hospital, where he was admitted for treatment.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1516433.015 | 54 | M | Hospitalized injury | Supervisors, production occupations |