Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 138211.015 - Employee sustains fingertip amputations on mechanical power

Accident Summary Nr: 138211.015 -- Report ID: 0552652 -- Event Date: 07/28/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1547125.01508/12/2021331315Linn Products Inc

Abstract: At 6:15 a.m. on July 28, 2021, Employee #1, a cell team leader, was observing a mechanical power press operated by two operators. Without communication, signal, or warning, the employee inexplicably reached into the die while the operators cycled the press using compliant two-hand controls. The employee sustained amputations to the ring and middle fingertips on the right hand, to the first knuckle, and was treated without hospitalization.

Keywords: Amputated, Amputation, Die, Finger, Fingertip, Hand, Knuckle, Mechanical Power Press, Power Press, Reaching In

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1547125.015 52 F Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.