Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 137966.015 - Employee fractures forearm when caught between ram and slab

Accident Summary Nr: 137966.015 -- Report ID: 0521100 -- Event Date: 05/17/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1532866.01505/26/2021311513Great Lakes Cheese, Inc.

Abstract: At 10:30 p.m. on May 17, 2021, an employee working as a machine operator for a cheese manufacturer noticed a coworker having problems with a slab cutter on Line 11. The coworker was pushing a new block of cheese through the cutter. As the block went through the harp wires, the coworker noticed that one of the harp wires had snapped. The wire did not come out of the block and his initial attempts to pull the wire out had failed. When the employee saw what was going on he came over to help the coworker with the jam. The employee asked the coworker to step back because he was going to move the ram forward and attach the broken wire to the ram. The employee stated that he was going to use the ram to pull the wire free of the block. The employee then activated the ram in automatic mode and waited for the ram to come close enough to attach the wire. As the ram was moving, the employee attempted to attach the wire but did not have enough time and was not able to remove his hand before the ram traveled all the way forward. The ram pinched the employee's forearm between the ram and the frame of the slab cutter. The employee was hospitalized to treat a fractured forearm requiring pins.

Keywords: Arm, Caught Between, Crushed, Cutter, Cutting, Engineering Controls, Food processing, Forearm, Fracture, Hand, Jammed, Lack of Engineering Controls, Lockout, Lockout/Tagout, Machine Guarding, Machine operator, Malfunction, Mech Malfunction, Metal Wire, Misjudgment, Misjudgment of Hazardous Situation, Pin, Pinch Point, Pinched, Point Of Operation, Power Press, Press, Ram

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1532866.015 35 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close