Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 137345.015 - Employee suffers right arm amputation when caught between co

Accident Summary Nr: 137345.015 -- Report ID: 0419400 -- Event Date: 06/02/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1534456.01506/03/2021321113Winona Hardwood, Inc.

Abstract: At 4:00 p.m. on June 2, 2021, Employee #1 was unloading edger trim pieces from a conveyor when he reached between the rotating belt and the tail end drum. His right arm was caught between the belt and drum, resulting in an amputation. The end of the conveyor was not guarded. Employee #1 was hospitalized for treatment.

Keywords: Amputated, Amputation, Arm, Belt, Belt Conveyor, Caught Between, Caught By, Caught In, Conveyor Belt, Machine Guarding, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1534456.015 37 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.