Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 137163.015 - Employee crushes left hand when caught in hydraulic press br

Accident Summary Nr: 137163.015 -- Report ID: 0626300 -- Event Date: 04/20/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1526478.01504/22/2021332322Ruskin Rooftop Systems, Llc

Abstract: At 8:22 a.m. on April 20, 2021, an employee working as a fabricating machine operator for a sheet metal manufacturer was operating the B7 Accurpress Model 7606 Hydraulic Press Brake. The employee was using the press brake to bend metal parts. He did not realize he had his hand too far up under a part while supporting it and holding it against the backrest of the machine. The employee had his left-hand fingers positioned between the part and the bottom die. As the press brake came down to make the bend it crushed the employee's left hand. The employee was hospitalized and required surgery on his hand.

Keywords: Bending Machine, Caught Between, Caught In, Crushed, Die Safety Device, Finger, Fracture, Hand, Machine Guarding, Machine operator, Mechanical Power Press, Metal, Metal Sheet, Misjudgment, Misjudgment of Hazardous Situation, Point Of Operation, Press Brake, Safety Device, Sheet Metal, Unsafe Position

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1526478.015 23 M Hospitalized injury Fabricating machine operators, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.