Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 136777.015 - Two employees sustain CO poisoning while mixing strong chemi

Accident Summary Nr: 136777.015 -- Report ID: 0626600 -- Event Date: 05/08/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1529933.01505/10/2021325320Stoller Usa, Inc.

Abstract: At 1:10 p.m. on May 8, 2021, two employees working for a chemical manufacturer were mixing chemicals to make an agricultural growth stimulator. The employees has added granular urea to the blend tank before adding in formic acid. The employees mixed 445.9 pounds of 98% sulfuric acid with 1645.5 pounds of 99% formic acid in a chemical tote. Mixing highly concentrated sulfuric acid with highly concentrated formic acid is known to cause the formic acid to degrade into carbon monoxide and water. Employee #1 lost consciousness twelve minutes after mixing the chemicals. Employee #2 lost consciousness two minutes later while helping Employee #1. Employee #1 was hospitalized and Employee #2 received medical treatment without hospitalization for carbon monoxide poisoning.

Keywords: Breathing, Carbon Monoxide, Chemical, Chemical Exposure, Chemical Reaction, Chemical Vapor, Engineering Controls, Inhalation, Lack of Engineering Controls, Lack of Work Procedures, Loss of consciousness, Lost consciousness, Lung, Misjudgment, Misjudgment of Hazardous Situation, Pesticide, Respirator, Respiratory, Respiratory Tract, Sulfuric Acid, Tote Box, Unconsciousness, Ventilation

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1529933.015 22 M Non Hospitalized injury
2 1529933.015 53 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.