Accident Summary Nr: 136426.015 - Employee fractures back in fall from manhole ladder to floor

Accident Summary Nr: 136426.015 -- Report ID: 0950633 -- Event Date: 08/14/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1528489.01504/29/2021238210Diversified Utility Services, Inc

Abstract: At 1:00 p.m. on August 14, 2020, an employee working as an electrician for an electrical utility contractor was climbing into a manhole after finishing a job. The employee needed to take some pictures. While climbing down the ladder, the employee grabbed hold of a pin from the manhole lid to steady himself. The pin broke loose causing the employee to fall to the concrete floor below. The employee was hospitalized to treat a fractured back and dislocated shoulder.

Keywords: Arm, Back, Blunt force, Blunt force trauma, Broke, Climbing on Ladder, Concrete Floor, Construction, Descending, Descending Ladder, Dislocated, Elec Utility Work, Electrician, Fall, Fall From Elevation, Fracture, Installing, Ladder, Lost Balance, Manhole, Manhole Cover, Shoulder, Undrgrd Installation, Unsafe Position, Unstable Position, Utility

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1528489.015 38 M Hospitalized injury Electrical power installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.