Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 136212.015 - Employee is killed when crushed on guardrails

Accident Summary Nr: 136212.015 -- Report ID: 0627700 -- Event Date: 06/07/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1535668.01506/07/2021213112Kleen Oilfield Services, Inc.

Abstract: On June 7, 2021, an employee was working from a rod basket performing gas and oil well servicing operations removing sucker rods and a subsurface pump. The employee was hanging the sections of three sucker rods onto a derrick. During the removal of the rods the employee attached a transfer cable and swivel to a string of rods and released the elevators attached to blocks before the bottom section was supported by the bottom elevators. This caused the entire string weight to be placed onto the transfer cable (a 5/16 wire rope) resulting in a rope break. When the rope broke, a cable clamp attached to the rope snagged the employee's SLR cable, pulling the employee down onto the top of the guardrail and sucker rods hanging in the derrick. The employee was crushed when he was pinned to the guardrails and rod basket. The employee suffered injuries to his abdomen and asphyxiation and was killed.

Keywords: Abdomen, Asphyxiated, Basket, Broken Cable, Chest, Crushed, Derrick, Derrickman, Elevator, Guardrail, Hoist, Hoisting Mechanism, Hoistline, Material Handling, Oil Well Drilling/Servicing, Oil Well Servicing, Pinned, Struck Against, Wire Rope

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1535668.015 52 M Fatality Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close