Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 136176.015 - Employee sustains multiple fractures when crushed by dumbwai

Accident Summary Nr: 136176.015 -- Report ID: 0950632 -- Event Date: 11/21/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1503904.01511/23/2020238290Thyssenkrupp Elevator Corporation

Abstract: At 7:30 p.m. on November 21, 2020, an employee working as a journeyman elevator technician for an elevator maintenance contractor had been tasked with troubleshooting and repairing a Matot Ambassador Dumbwaiter, State ID # 119818, that was malfunctioning. The employee had over 30 years of experiencing working as a mechanic on elevators and had worked on dumbwaiters in the past. The employee had been on-call when he received a dispatch to the grocery store to perform a fairly routine task. The employee began to troubleshoot the unit at which time he entered the hoist way of the dumbwaiter through the door of the adjacent unit from the first floor. The employee had failed to lock and tag out the electrical disconnect for the dumbwaiter units and had removed a sign that indicated work was being done within. The employee grabbed a broom in order to use the handle to manipulate the door of the malfunctioning unit. While the employee was performing his work, a coworker who worked for the grocery store called an adjacent dumbwaiter unit. The unit caught the employee and dragged him upwards to the second floor trapping the employee. The responding Fire Department had to cut a piece of angle iron in order to extract the employee. The employee was hospitalized to treat crush injuries including multiple fractures to his chest. The employee was discharged after 11 days.

Keywords: Catch Point, Chest, Crushed, Elevator, Fracture, Installing, Lockout, Lockout/Tagout, Maintenance, Mechanic, Misjudgment, Misjudgment of Hazardous Situation, Multi-employer Worksite, Multiemployer, Repair, Struck Against, Troubleshooting, Unsafe Position, Warning Sign

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1503904.015 66 M Hospitalized injury Elevator installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.