Accident Summary Nr: 136087.015 - Employee loses consciousness when struck by trailer chain

Accident Summary Nr: 136087.015 -- Report ID: 0418100 -- Event Date: 01/14/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1513004.01501/25/2021237310G.P.'S Enterprises, Inc.

Abstract: At 9:15 a.m. on January 14, 2020, Employee #1, employed by a construction company, was attempting to lift the stinger portion of a lowboy trailer to insert shim material. The chain slipped off the trailer and struck the employee in the head. The employee lost consciousness. He was transported to the hospital and admitted for treatment of the injuries.

Keywords: Blunt force trauma, Chain, Equipment Operator, Falling Object, Head, Lost consciousness, Struck By, Trailer, Truck Driver, Unconsciousness

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1513004.015 54 M Hospitalized injury Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.