Accident Summary Nr: 135920.015 - Employee falls and is killed after bucket on crane broke off

Accident Summary Nr: 135920.015 -- Report ID: 0524530 -- Event Date: 05/28/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1533631.01505/29/2021339950Jenkins Displays Co.

Abstract: At approximately 3:13 p.m. on May 28, 2021, an employee was working in a personnel basket that was connected to a boom of truck crane. The crane was a Sky Hook, Model 130 boom, and was mounted to a flatbed trailer. The trailer was a Monon Corporation, Model OD 100a 10 trailer with a serial number of 1NNJOO1XLM139006. The employee was with two other workers on the site. The weather was overcast and dry. The employee was attempting to remove a frame of a backlit sign fixture to replace the plastic insert with a new one. The crane did not have any controls in the basket to control the height of the boom but did have a manual leveling device to secure the angle of the basket. No attachment point was discovered for fall protection on either the basket or the boom. The crane had only a visual operations inspection by the users prior to its use. The crane had not been inspected for defects. The basket was attached to the boom by a tube that was bent and damaged near the connection point. During the removal of the frame, the employee fell approximately 60 feet to a concrete/asphalt parking lot. The employee fell when the basket separated from the boom. The employee received blunt trauma injuries to his head and chest that resulted in the death of the employee.

Keywords: Blunt force, Blunt force trauma, Crane, Crane Boom, Fall

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1533631.015 41 M Fatality Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close