Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 135834.015 - Tree trimmer falls from tree when chain saw cuts safety line

Accident Summary Nr: 135834.015 -- Report ID: 0950621 -- Event Date: 04/15/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1532827.01505/20/2021561730International Tree Management, Inc.

Abstract: At 12:20 p.m. on April 15, 2021, an employee was working for a tree trimming service. He was a foreman. He and two coworkers had been sent to work in a county forest. No other firm was working onsite at the time of the incident. The workers were piecing down a sugar pine tree. In this incident, the employee was working aloft in the tree, piecing it down. His two coworkers were on the ground, working as groundsmen. The sugar pine was dying and had been scheduled for removal, It was some 95 feet (29 m) tall and some 26 in. (0.66 m or 660 mm) across Presumably, the diameter was taken at breast height. The employee had completed six cuts off the top of the tree with traditional cuts. He then switched to a larger chain saw, a Stihl model MS362, to make the seventh cut, a Humboldt cut this time. This would have resulted in a 16-ft by 14-in. (4.9-m by 360-mm) piece. After he had completed the cut, a pie-shaped or wedge-shaped piece remained in the tree. To remove the piece, the employee used the top of the chain saw blade to knock out the piece. The chain saw's blade kicked off the surface of the tree and cut both of the employee's safety lines. The employee fell nearly 45 feet (13.7 M) onto a bed of pine needles. He suffered a fractured wrist, a dislocated shoulder, and some fractured ribs. He was hospitalized. DOSH learned of the incident at approximately 11:00 a.m. on the following day, April 16, 2021, when the employer reported it with a phone call. The employer reported the incident within the required timeframe. DOSH arrived at the incident site at approximately 9 a.m. on May 20, 2021. The site was no longer active. Because the employer was located in Southern California, an opening conference was conducted over a phone line that day. No accident-related citations were to be issued.

Keywords: Arboriculture, Arborist, Broken Bone, Chain Saw, Chest, Climbing Line, Cut, Dislocated, Fracture, Kick Back, Misjudgment, Misjudgment of Hazardous Situation, Rib, Rope, Shoulder, Tree, Tree Trimming, Wrist

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1532827.015 46 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close