Accident Summary Nr: 134639.015 - Employee's finger is partially amputated by hydraulic clamp

Accident Summary Nr: 134639.015 -- Report ID: 0418300 -- Event Date: 03/29/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1524023.01504/05/2021332323Construction Services, Inc.

Abstract: At 9:20 a.m. on March 29, 2021, Employee #1 was shearing a 1'x1' aluminum sheet into three-inch wide strips on a Cincinnati Century Series Hydraulic Shear (Serial Number 3C080, 19799). While operating the machine, the employee's finger accidentally went under the awareness barrier to the hold-down clamp and was struck by the hydraulic dog after activating the foot pedal. The employee suffered a partial finger amputation and was provided with medical treatment, but was not hospitalized.

Keywords: Amputated, Amputation, Automatic Machine, Clamp, Finger, Fingertip, Foot pedal, Hydraulic, Partial Amputation, Shear, Struck Against, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1524023.015 55 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close