Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 134621.015 - Employee amputates finger when bypasses guard

Accident Summary Nr: 134621.015 -- Report ID: 0524700 -- Event Date: 03/30/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1523887.01504/07/2021325212Johnson Bros. - Greenwich, Inc.

Abstract: At 2:30 p.m. on March 30, 2021, an employee was working on the rubber cutting line, removing and weighing rubber pieces after he exited the rubber strip cutting machine. Some of the cut rubber pieces were sticking to the blade or not falling to the bottom of the exit chute, so the employee would reach in under the guard to retrieve the rubber to weigh and rack. The employee had retrieved two pieces of rubber with no issue, and then, when he went to grab the third piece, the blade came down on his right index finger, amputating the whole finger. The employee was hospitalized. At the time of the accident, the cutting machine did have a clear plastic guard with an interlock to prevent operation if the guard was opened, however there was an opening below the guard approximately 25 inches wide by 11 inches high, which could allow an employee to access the blade area without opening the interlocked guard.

Keywords: Amputated, Amputation, Blade, Blind Reaching, Bypass, Bypass Guard, Cutting, E GI VI (blind reaching), Finger, Guard, Interlock, Reaching In, Removing, Rubber

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1523887.015 41 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.