Accident Summary Nr: 134465.015 - Employee catches finger between paper roll core and air bar

Accident Summary Nr: 134465.015 -- Report ID: 0552652 -- Event Date: 03/12/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1522777.01503/31/2021323120Sheridan Publishing

Abstract: At 12:15 p.m. on March 12, 2021, Employee #1 was loading a new roll of paper and removing the expired paper roll core at a printing press feed stand. While performing these tasks, the employee's finger became caught between the air bar shaft groove and the core of the paper roll. The employee sustained an amputation to the right ring finger and was treated without hospitalization.

Keywords: Amputated, Amputation, Caught Between, Caught By, Caught In, Finger, Fingertip, Lockout/Tagout, Machine Guarding, Paper, Paper Roll, Pinch Point, Pinched, Tagout

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1522777.015 58 M Non Hospitalized injury Printing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.