Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 134410.015 - Employee partially amputates thumb when glove is caught in n

Accident Summary Nr: 134410.015 -- Report ID: 0521100 -- Event Date: 03/10/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1520102.01503/17/2021321113T & T Quality Cutting, Llc

Abstract: At 10:45 a.m. on March 10, 2021, an employee was operating a wood stacking machine. The employee leaned against the frame weldment of the dog-ear machine to wait for additional boards to come down the transfer deck. The employee placed his hand behind his back on the frame weldment next to a chain and sprocket covered by a 2-inch deep by 4-inch wide by 36-inch guard. The employee's glove was caught in the ingoing nip-point of the chain and sprocket underneath the guard, resulting in the right thumb being partially amputated. The employee was treated without hospitalization.

Keywords: Caught In, Chain, Finger, Glove, Guard, Machine operator, Nip Point, Partial Amputation, Sprocket, Thumb, Wood

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1520102.015 19 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.