Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 133766.015 - Two employees burn faces when chemical batch boils over

Accident Summary Nr: 133766.015 -- Report ID: 0636900 -- Event Date: 10/30/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1504022.01511/20/2020325180Kurita America

Abstract: At 8:00 p.m. on October 30, 2020, Employee #1 and Employee #2, both chemical technicians working for a chemical manufacturer, were preparing a batch of Kuriverter IK-110. The process requires that employees manually add constituent chemicals into a blending tank where a reaction occurs. During the operation, the employees control the reaction by monitoring the temperature of the product and adjusting the rate at which chemicals are added if the temperature begins to raise above an established threshold. During the later stages of the preparation, the employees became aware that they had chosen a blending tank that was too small to hold the final volume of the finished product. To correct the problem, they placed the remainder of the chemical that had not been added to the mixture into an empty but larger blending tank. The employees then transferred the already mixed chemicals from the smaller tank into the larger one. Upon doing so an uncontrolled reaction occurred causing the corrosive chemicals to boil over onto both Employee #1 and Employee #2. Both employees were hospitalized to treat chemical burns to their faces.

Keywords: Burn, Chemical, Chemical Burn, Chemical Reaction, Corrosive, Face, High Temperature, Insufficient Supervision, Lack of Work Procedures, Lost Control, Material Handling, Misjudgment, Misjudgment of Hazardous Situation, Mixer, PPE, PPE Hazard Assessment, Protective Clothing, Tank, Technician, Wrong Equipment

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1504022.015 22 M Hospitalized injury Chemical technicians
2 1504022.015 22 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.