Accident Report Detail
Accident Summary Nr: 133080.015 - Employee is killed when asphyxiated while wearing supplied a
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1513695.015 | 02/05/2021 | 332312 | Brilex Industries Inc. |
Abstract: At 5:00 p.m. on February 4, 2021, an employee was working for a firm that manufactured fabricated structural metal. He was performing abrasive blasting with steel shot. He was wearing a supplied air respirator (SAR). While using the supplied air hood, he lost consciousness. A pressure testing operation downstream on the plant air line allowed nitrogen to backfill into the compressed air line. This test introduced an asphyxiant into the system. The employee was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury |
|---|---|---|---|---|---|
| 1 | 1513695.015 | 62 | M | Fatality |
Translate