Accident Summary Nr: 132885.015 - Employee incurs multiple injuries when struck by elevator do

Accident Summary Nr: 132885.015 -- Report ID: 0418300 -- Event Date: 01/19/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1512600.01501/27/2021311615Pilgrim'S Pride Corporation

Abstract: At 10:48 p.m. on January 19, 2021, an employee was reaching into a vertical reciprocating conveyor (VRC), or full-size freight elevator lift box, to remove packaging supplies. The two #35 master links that connect the chains on each side of the gate to the counterweights failed, and the inner gate fell down onto the employee and knocked her down to the ground. The door bounced back up, then fell back down again onto the employee's leg. The employee was hospitalized to treat a fractured tibia and fibula, compression fractures to vertebrae, and a collapsed lung.

Keywords: Blind Reaching, Chain, Collapsed lung, Conveyor, Counterweight, Door, E GI VI (blind reaching), Elevator, Equipment Failure, Fibula, Fracture, Gate, Knocked from, Leg, Packaging, Reaching, Reaching In, Removing, Struck By, Tibia, Vertebra

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1512600.015 48 F Hospitalized injury Miscelaneous food preparation occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.