1512237.01501/28/2021111991Coma Farms, Llc

Abstract: At 8:30 a.m. on January 27, 2021, an employee began the work process to put a new conveyor belt on a 2006 Peterbilt 10 Wheeler Dump Truck equipped with a Logan Potato Bed. The employee became entangled in the conveyor drive shaft breaking his neck and arms and killing him.

Keywords: Arm, Automotive Repair, Caught In, Conveyor, Conveyor Belt, Crushed, Drive Shaft, Dump Truck, Dump Truck Bed, Dumper, Entangled, Maintenance, Neck, Repair, Roller Conveyor, Rotating Parts, Rotating Shaft, Shaft, Truck

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1512237.015 35 M Fatality Farm equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.