Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 132191.015 - Employee is crushed when pulled into recoiler, later dies

Accident Summary Nr: 132191.015 -- Report ID: 0522500 -- Event Date: 01/05/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1508844.01501/06/2021332111Champion Strapping Products, Inc.

Abstract: At 2:30 p.m. on January 5, 2021, an employee was operating a steel strapping line with an uncoiler, wax machine, slitter and recoiler. The employee attempted to place a piece of folded paper by hand into the recoiler to create volume within the coil while it was running. The employee's right hand/arm was pulled into the recoiler's ingoing nip point where the steel met the rotating coil, causing the employee to be pulled over the top and under the recoiler. The employee was trapped and later died at the hospital. The employee received crushing injuries to the arm, head and chest.

Keywords: Arm, Caught By, Caught In, Chest, Crushed, Crushing, Equipment Operator, Hand, Head, Nip Point, Operator, Roller--Mach/Part, Rotating Shaft, Steel

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1508844.015 38 M Fatality Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.