Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 131905.015 - Employee dies after fall from site-built scaffold

Accident Summary Nr: 131905.015 -- Report ID: 0453710 -- Event Date: 12/01/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1507646.01512/07/20201522236118147058 - Cates Contracting

Abstract: On December 1, 2020, Employee #1, employed by a home remodeler, was working at a job site. He was attempting to construct a scaffold/platform with 2 by 6 boards of lumber. As he accessed a board, it broke, causing him to fall to the concrete surface, a fall height of 12 feet 8 inches. Emergency services transported the employee to the hospital, where he was admitted for treatment of severe head trauma. Employee #1 died the following day, December 2, 2020.

Keywords: Blunt force trauma, Elevated Work Platform, Fall, Fall Protection, Head, Remodel, Residential Construction, Scaffold, Structural Collapse

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1507646.015 47 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.