Accident Summary Nr: 131577.015 - Employee's fingers are amputated in die cutter

Accident Summary Nr: 131577.015 -- Report ID: 0552652 -- Event Date: 11/13/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1505585.01512/08/2020322211Kentwood Packaging Corporation

Abstract: At 11:00 a.m. on November 13, 2020, an employee was cleaning ink splatter from the rollers on the 300-die cutter machine, while the machine was in run mode. The rollers caught his glove/sleeve and pulled his right hand into the rollers. The employee sustained an amputation of three of his right fingers and was hospitalized.

Keywords: Amputated, Amputation, Caught By, Cleaning, Clothing, Die Cutting Press, Finger, Glove, Pulled In, Roller--Mach/Part, Running

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1505585.015 70 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.