Accident Summary Nr: 131502.015 - Employee fractures vertebrae and clavicle when struck by fal

Accident Summary Nr: 131502.015 -- Report ID: 0751910 -- Event Date: 12/05/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1505115.01512/07/2020532412Wilkerson Crane Rental, Inc.

Abstract: At 1:30 p.m. on December 5, 2020, an employee was working for a firm that rented or leased construction cranes. He worked as a crane and tower operator. He was at a wind farm. He was dismantling a Liebherr LTM 1400 crane. He was removing a button head single-tapered pin from the crane's jib. He was working under the jib while removing the pin. The jib was not adequately rigged or supported during disassembly. As the employee removed the single-tapered pin from the jib, the jib fell onto the employee. He suffered fractured vertebrae and a fractured clavicle. He was hospitalized. The manufacturer recommended that a double-tapered pin be used, so that the pin could be safely removed by an employee standing on the outside of jib during disassembly. During this crane's assembly, workers had used a single-tapered button pin. The use of the single-tapered button pin resulted in the employee's being in an unsafe position during disassembly. This condition resulted in a struck-by hazard, as noted during an inspection two days later, on December 7, 2020.

Keywords: Clavicle, Construction, Crane, Disassemble, Falling Object, Fracture, Jib Crane, Lack of Work Procedures, Pin, Struck By, Utility, Vertebra, Wind Farm, Wind Tower
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Alteration or rehabilitation  

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1505115.015 30 M Hospitalized injury Crane and tower operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.