Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 131217.015 - Employee is killed during trench collapse

Accident Summary Nr: 131217.015 -- Report ID: 0213600 -- Event Date: 11/18/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1503096.01511/18/2020238910D&H Excavating, Inc

Abstract: At 4:30 p.m. on November 18, 2020, Employee #1, employed by a construction excavation company, was working on a pipeline installation project. He was in a trench and tightening bolts on an end cap. A section of the trench sidewall collapsed and struck the employee, causing him to fall and strike his head on a plumbing valve. The employee sustained blunt force traumatic injury to his head and was killed.

Keywords: Blunt force trauma, Brain, Cave-In, Construction, Excavation, Head, Skull, Struck Against, Struck By, Structural Collapse, Trench, Unprotected, Valve, Wall
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1503096.015 25 M Fatality Construction Laborer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.