Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 131089.015 - Employee is killed while cleaning tank trailer

Accident Summary Nr: 131089.015 -- Report ID: 0626600 -- Event Date: 11/12/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1502394.01511/13/2020811118Flash Tank Services, Inc.

Abstract: At 4:00 p.m. on November 12, 2020, an employee entered a tank trailer to clean it. The last cargo hauled in the tanker was toluene. The employee was found unresponsive in the tank trailer. The employee died of acute toluene toxicity.

Keywords: Chemical Exposure, Cleaning, Tank Cleaning, Tank Truck, Toluene, Toxic Fumes, Unresponsive

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1502394.015 54 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.