Accident Summary Nr: 130325.015 - Employee dies after falling from unguarded platform basket

Accident Summary Nr: 130325.015 -- Report ID: 0855610 -- Event Date: 10/06/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1495897.01510/06/2020236115Viking Development Llc

Abstract: On October 6, 2020, Employee #1, employed by a construction company, was working at a multi-employer construction project for a new residential structure. He was using a SkyTrak Rough Terrain Forklift with a homemade platform basket and installing exterior siding. The platform basket had no side rails, and the employee was not using a personal fall arrest system. The employee walked backward on the platform and fell from the unguarded right side, a fall height of 17 feet. He hit his head on a concrete patio. Emergency services transported the employee to the hospital, where he died of fall-related injuries two weeks later.

Keywords: Aerial Lift, Basket, Blunt force trauma, Brain, Concrete Slab, Elevated Work Platform, Fall, Fall Protection, Forklift, Guardrail, Head, Installing, Open-Sided Floor, Residential Construction, Siding, Skull, Struck Against, Unguarded, Walking Backward, Work Surface
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition   2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1495897.015 44 M Fatality Carpenters Distance of Fall: 17 feet
Worker Height Above Ground/Floor: 17 feet
Cause: Installing metal siding
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.