Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 130214.015 - Four of employee's fingers are amputated by dry ice machine

Accident Summary Nr: 130214.015 -- Report ID: 0317300 -- Event Date: 10/09/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1496712.01510/09/2020325180Praxair Distribution, Inc.

Abstract: At 6:45 a.m. on October 9, 2020, a 68-year-old employee was working for a firm that manufactured industrial gases, such as nitrogen, oxygen, carbon dioxide, argon, hydrogen, helium, and acetylene. He worked in machinery maintenance. He was at the firm's dry ice (solid carbon dioxide) production facility. He was troubleshooting an IceTech SL1000 dry ice making machine. The blocks of dry ice it was making were not being formed correctly. The employee began troubleshooting the machine by opening the access door to the ice box to inspect the machine. When the employee reached into the ice box where a loosely packed ice block was sitting, the fingers on his left hand were inadvertently caught in a rotating part within the ice box. The employee suffered the amputation of four fingers on his left hand. The employee was hospitalized. The narrative implies that the amputations happened instantaneously rather than during surgery later. Following the incident, the employer added an energy control system that implemented an energy control device to all their dry icemaking machines in the U. S. This system isolated the hazardous energy that energized the rotating part within ice boxes, the part that cause the employee injury in this case. An interlock system comprising an interlock device and machine interface electronic programming was instituted to prevent the rotation of this part by shunting the flow of electrical power away from any electronic components (e. g., accentuator, motor, etc.) whenever the door to an ice box was in the open position.

Keywords: Amputated, Amputation, Blind Reaching, Carbon Dioxide, Caught By, Elderly, Finger, Instantaneous amputation, Lockout, Lockout/Tagout, Machine Guarding, Maintenance, Misjudgment, Misjudgment of Hazardous Situation, Reaching, Reaching In, Rotating Parts, Traumatic Amputation, Troubleshooting

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1496712.015 68 M Hospitalized injury Machinery maintenance occupations
2 1496712.015 68 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.