Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 129411.015 - Employee amputates fingertip in dust silo hopper

Accident Summary Nr: 129411.015 -- Report ID: 0419700 -- Event Date: 09/05/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1492292.01509/10/2020325194Lignotech Florida, Llc

Abstract: At 2:00 a.m. on September 5, 2020, an employee was monitoring the controls inside the DCS room. The employee believed there was a blockage in the section of piping of the vacuum system underneath the rotary valve. He reached his hand into the unguarded area to pinch some material to verify it was clogged and made contact with rotary valve blades. The employee was hospitalized to treat an amputation to the tip of right index finger.

Keywords: Amputated, Amputation, Blade, Blind Reaching, Clogged, E GI VI (blind reaching), Finger, Fingertip, Hopper, Reaching In, Rotating Parts, Silo, Unguarded, Valve

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1492292.015 31 M Hospitalized injury Operations & systems researchers and analysts

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.