Accident Summary Nr: 128786.015 - Employee amputates four fingers when pulled into crane sheav

Accident Summary Nr: 128786.015 -- Report ID: 0419700 -- Event Date: 08/12/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1488971.01508/18/2020237310Skanska Usa Civil Southeast, Inc.

Abstract: At 1:30 p.m. on August 12, 2020, an employee working as an equipment operator for a construction contractor was lubricating the 1-inch wire ropes on a crane. While spraying the oil onto the cables, the employee was holding a rag in his right hand to shield overspray. While the cable was winding onto the cable drum, the rag snagged on the moving cable and pulled the employee's hand into the cable sheave. The employee amputated four fingers on his right hand and was hospitalized.

Keywords: Amputated, Amputation, Cable, Caught Between, Crane, Equipment Operator, Finger, Guide, Hand, Instantaneous amputation, Lack of Work Procedures, Lubricating, Lubricating Fluid, Maintenance, Material Handling, Misjudgment, Misjudgment of Hazardous Situation, Pulled In, Rag, Traumatic Amputation

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1488971.015 60 M Hospitalized injury Equipment Operator: Skidsteer/Bobcat

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.