Accident Report Detail

Accident Summary Nr: 128717.015 - Employee's left hand is crushed in square-up machine

Accident Summary Nr: 128717.015 -- Report ID: 0552652 -- Event Date: 05/18/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1486015.01507/30/2020333514Digital Tool & Die, Inc.

Abstract: At 10:15 a.m. on May 18, 2020, a nineteen-year-old employee was working for a firm that manufactured special dies and tools, die sets, jigs, and fixtures. He was a machine operator. He was operating an Amada machine. He was squaring a block of steel on the machine. He was not using the required hand tool to hold the steel block in place. He inadvertently pushed a wrong button, the one that activated the clamping device. The squaring block clamped the employee's left hand. The employee's left hand and finger were crushed. The employee was treated without hospitalization.

Keywords: Clamp, Crushed, Finger, Hand, Hand Tool, Hold-Down Clamp, Inexperience, Machine Cycled, Machine operator, Push Stick, Training, Work Rules

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1486015.015 19 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close