Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 128515.015 - Employee is killed by falling concrete conveyer assembly

Accident Summary Nr: 128515.015 -- Report ID: 0751910 -- Event Date: 08/10/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1487642.01508/11/2020237310Streb Construction Co., Inc.

Abstract: At 10:00 a.m. on August 10, 2020, an employee was working for a firm that constructed highways, streets, and bridges. He was the operator of a combination PS-2700 Power Paver and CMI PS3202 two-track belt placer/spreader. At the time, two maintenance workers were servicing the hydraulic system of the PS-2700 Power Paver's conveyer belt. They were working on the PS-2700 Power Paver's CMI PS3202 concrete conveyor assembly. They had taken the conveyer assembly out of service in an elevated position, because one of its two hydraulic cylinder pistons was displaced from the knuckle attachment. The two maintenance workers were actuating the piston rod into its extended position so that they could temporarily weld the piston to the knuckle case. The maintenance workers could then lower the conveyor belt to the ground, replace the hydraulic cylinders, and return the machine to service. As one maintenance worker was actuating the hydraulic piston, the machine operator was walking next the elevated conveyer belt. As the employee walked under the elevated conveyor system, the hydraulic system failed, and the belt assembly fell unexpectedly. The employee was struck by the falling equipment and was trapped between the belt assembly and the ground. The area around the machine was not marked, and the employee was wearing a high visibility vest. He sustained multiple crushing injuries, and he was killed.

Keywords: Belt Conveyor, Concrete, Construction, Conveyor Belt, Crushed, Equipment Operator, Falling Object, Lockout, Maintenance, Road Paving, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1487642.015 61 M Fatality Equipment Operator: Heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close