Abstract: At 11:00 a.m. on July 10, 2020, Employee #1 and Employee #2 were placing concrete blocks within the minimum approach distance of energized 100,000-volt overhead transmission lines with a Link Belt TCC 750 crane. While moving loads of blocks, the crane contacted the lines conducting electricity towards the employees. The two employees were hospitalized to treat electric shock injuries.

Keywords: Concrete Block, Construction, Contact, Electric Conductor, Electric Shock, Mobile Crane, Overhead Power Line
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant Alteration or rehabilitation  

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1482849.015 30 M Hospitalized injury Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Forming
Fatality Cause:
2 1482849.015 40 M Hospitalized injury Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Forming
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.