Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 127681.015 - Employee amputates fingers while operating press forming par

Accident Summary Nr: 127681.015 -- Report ID: 0524500 -- Event Date: 07/07/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1482899.01507/10/2020332510Lyon, Llc

Abstract: At 11:00 p.m. on July 7, 2020, an employee was operating a press brake forming parts when he caught his left hand between the dies (point of operation) on the press. The employee amputated four fingers and was hospitalized.

Keywords: Amputated, Amputation, Caught Between, Die, Finger, Guard, Hand, Machine Guarding, Machine operator, Mechanical Power Press, Pinched, Point Of Operation, Power Press, Press Brake, Press Operator, Shear, Sheared, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1482899.015 25 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.