Accident Summary Nr: 127680.015 - Two employees are asphyxiated in sewer line manhole

Accident Summary Nr: 127680.015 -- Report ID: 0626600 -- Event Date: 07/09/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1482885.01507/10/2020562998Kleen Environmental, Llc

Abstract: At 11:30 a.m. on July 9, 2020, Employees #1 and #2 and their foreman, employed by a waste management company, were installing a closed circuit television (CCTV) into an 8-inch sewer line to enable inspections in the manhole. They did not test the atmosphere before attempting to enter the manhole, which met the definition of confined space, and ventilation equipment was not available. Employee #1 entered the 12-foot deep manhole to remove a plug that controlled the flow of water and was overcome by the release of water and sewer gases that included toxic hydrogen sulfide. Employee #2 entered the manhole to provide assistance, was overcome by the sewer gases, and fell from the rope ladder he was using to the bottom of the manhole. The foreman was unable to rescue the employees. A 3M Confined Space Tripod system was onsite but not set in place. Employee #1 and Employee #2 both died in the manhole.

Keywords: Asphyxiated, Climbing on Ladder, Confined Space, Construction, Fall, Hydrogen Sulfide, Inspecting, Installing, Manhole, Overcome by gas, Oxygen Deficiency, Pipeline, Sewer, Toxic Atmosphere, Ventilation, Water Pipe
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Maintenance or repair   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1482885.015 58 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:
2 1482885.015 44 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.