Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 127564.015 - Employee operating roller compactor is crushed in roll-over

Accident Summary Nr: 127564.015 -- Report ID: 0521400 -- Event Date: 07/02/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1482315.01507/07/2020237310Porter Brothers Construction, Inc.

Abstract: At 3:15 p.m. on July 2, 2020, Employee #1, employed by a civil construction company, was operating a Hyster C530A pneumatic roller compactor at a gravel road construction project. The equipment was compacting newly-poured rocks when it rolled off the road and into an embankment that had an approximate angle of 25 degrees. The equipment, which did not have roll-over protection, overturned and crushed the operator. Employee #1 was pronounced dead at the scene.

Keywords: Construction, Crushed, Embankment, Equipment Operator, Overturn, Pneumatic, Road Paving, Roll-Over, Roller--Const Equip, Run Over, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1482315.015 34 M Fatality Operating engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.