Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 127551.015 - Employee working on loader is killed when boom falls

Accident Summary Nr: 127551.015 -- Report ID: 0627510 -- Event Date: 07/06/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1482276.01507/06/2020112112Associated Supply Company Inc.

Abstract: At 11:00 a.m. on July 6, 2020, an employee was working as a service technician at a cattle feedlot. He had been working for the firm for about one year. He was the employee in charge at the worksite. He and a helper were performing maintenance on a front end loader or wheel loader. The helper had been working for the firm as a yard hand for about seven month. The loader had a hydraulic fluid leak on its right side. Because of the leak, the loader was losing hydraulic pressure on its right side. It was not able to hold its bucket up in the air. The helper was sitting at the controls in the cab. The employee had his helper raise the arms of the wheel loader with the bucket attached all the way up in the air. According to the maintenance supervisor, the bucket weighed approximately 2,300 to 3,600 kilograms (5,000 to 8,000 pounds). After the helper raised the arms up to their furthest extent, he turned off the wheel loader and exited the cab. Both employees walked under and stood under the raised load with no support at this time. The employee went to the left side of the loader to install the support strut and retaining bolt to the hydraulic cylinder. He was doing this so that he could begin performing the service and maintenance on the hydraulics on the right side. All this time, the arms of the loader were slowly falling until the weight of the bucket. The front end loader's boom and arms suddenly fell, striking the employee. The employee was crushed between the arm of the boom and a tire. He was killed. No certified hazard assessment had been performed before the start of work.

Keywords: Crushed, Equipment Failure, Falling Object, Front End Loader, Hydraulic Fluid, Leak, Lockout, Maintenance, Struck By, Wheel Loader

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1482276.015 35 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close