Accident Summary Nr: 127523.015 - Employee amputates finger and injures arm when pulled into a

Accident Summary Nr: 127523.015 -- Report ID: 0111700 -- Event Date: 04/13/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1472326.01504/13/2020423930Simple Life Recycling Llc

Abstract: At 9:45 a.m. on April 13, 2020, an employee working as a machine operator for a recycling company was cleaning out a shredder and screw auger conveyor. The employee was preparing to run a new batch of metal through the shredder. The employee tried to retrieve a piece of jammed metal when his arm was pulled into conveyor. The employee severely damaged his arm sustaining multiple breaks, lacerations, a dislocation and the amputation of one finger. The employee was hospitalized and required multiple surgeries.

Keywords: Amputated, Amputation, Arm, Auger, Auger Mechanism, Broken Bone, Catch Point, Conveyor, Dislocated, Jammed, Laceration, Lack of Engineering Controls, Lockout, Lockout/Tagout, Machine Guarding, Machine operator, Metal, Misjudgment, Misjudgment of Hazardous Situation, Pulled In, Safety Device, Screw Conveyor, Shredder, Traumatic Amputation

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1472326.015 25 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.