Accident Summary Nr: 127252.015 -- Report ID: 0636900 -- Event Date: 06/23/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1480460.01506/24/2020441222Premier Ski Boat Corporation

Abstract: At 8:55 a.m. on June 23, 2020, an employee was working for a boat dealer. He was using a Kubota tractor to move a boat and trailer located in the facility's shop bay. He connected the boat to the tractor and begun repositioning the boat. As the employee started moving the boat, the boat trailer disconnected from the tractor and continued moving toward some parked boats. A coworker, the lead technician, was present. He yelled to the employee to let the boat go. The employee got in front of the moving boat and between the moving boat and the parked boats to attempt to stop the disconnected moving boat. The employee was caught in between the boats when they collided. He was struck by the moving boat and pinned between it and the parked boats. He was killed. The lead technician felt that the cause of the incident was a failure to ensure that the trailer ball was secured in the hitch and to secure the safety pin in the hitch. The employer did not have a standard operating procedure (SOP) for moving vessels and trailers with the use of a Kubota tractor. It had one created on July 3, 2020. The employer was to provide the employees training on the importance of following the procedure when connecting the tractor to the vessel trailer. It covered inserting the safety pin, walking around the vessel to ensure that it was connected correctly, and verifying that the trailer was connected properly to the tractor.

Keywords: Boat, Caught Between, Crushed, Equipment Operator, Nip Point, Pinned, Restraining Device, Tractor, Trailer, Training, Work Rules

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1480460.015 31 M Fatality Buyers, wholesale & retail trade except farm prod.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close