Accident Summary Nr: 126665.015 - Employee fractures knee and ankle in crane accident

Accident Summary Nr: 126665.015 -- Report ID: 0950632 -- Event Date: 06/01/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1477427.01506/05/2020336611General Dynamic Nassco

Abstract: At 4:10 p.m. on June 1, 2020, a journeyman shipfitter (Coworker) was directed to move a steel plate that was located in a storage rack to a work table. Using a rigging clamp, the coworker stood on the elevated platform behind the storage rack so that he could attach the clamp to the steel plate. The production supervisor, Employee #1, came over and offered to help by taking the overhead crane controller that was located away from the storage rack. Employee #1 elevated the steel plate that was rigged to the overhead crane via a chain bridle and clamp. The steel plate was wedged between the other steel plates so there was not movement. Employee #1 came over and stood directly in front of the rack with the steel plate. Using the crane controller, Employee #1 lowered the clamp causing the chain bridle to catch on a corner on the steel plate. Standing in front of the rack with the steel plate, Employee #1 elevated the rig, causing the plate to flip forward and strike Employee #1. Employee #1 suffered a fractured knee and ankle, requiring hospitalization for more than 24-hours. The investigation revealed that Employee #1 was standing under a suspended load that he was controlling. Employee #1 should not have been in the zone of danger while the steel plate was being suspended by the overhead crane.

Keywords: Ankle, Chain, Clamp, Elevated Work Platform, Fracture, Knee, Moving, Overhead Crane, Rigging, Ship, Steel Plate, Storage Rack, Struck By, Suspended Load

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1477427.015 25 M Hospitalized injury Boilermakers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close