Accident Summary Nr: 126533.015 - Cable employee falls from ladder when pole snaps at base and

Accident Summary Nr: 126533.015 -- Report ID: 0751910 -- Event Date: 05/19/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1476785.01505/29/2020517310Windstream Communications, Llc

Abstract: At 2:00 p.m. on May 19, 2020, an employee was working for a cable television and internet service provider. He installed and repaired cable TV and internet connections. In this incident, he was installing or repairing a residential service drop that came in aboveground. The telecommunications cable was attached to a 20-foot tall (6.1-meter tall) wooden communications pole. The pole appeared to have been dedicated to communications. It was installed in 1944, so it probably carried a twisted-pair telephone line when it was put in place. The narrative did not state that the pole was also used by an electric utility. The pole was 7 in. (178 mm) in diameter. The employee leaned a Werner 24-foot (7.3-meter) extension ladder equipped with a V-rung attachment against the communications pole. The ladder was not secured to the pole. The employee was working approximately 12 feet (3.7 meters) above ground. He cut a tension wire that was ran from the pole to the residence. The wooden pole snapped back, broke at its base, and fell across an alley into a tree. The employee lost his footing and fell backward against his service truck. He landed on the gravel alley below. He suffered fractured ribs, unknown head injuries, and abrasions. Employee #1 struck the service vehicle and the ground. He was hospitalized for two or more days. He had not inspected the pole before starting work.

Keywords: Abrasion, Broken Bone, Communication Cable, Communication Worker, Extension Ladder, Fall, Fall From Elevation, Falling Object, Fracture, Hazard Assessment, Head, Inspection, Ladder, Rib, Service Technician, Struck Against, Telecom Work, Training, Truck, Unstable Position, Utility Pole

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1476785.015 61 M Hospitalized injury Telecomm: Line Installers And Repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.