Accident Summary Nr: 126411.015 - Employee's thumb is amputated on repackaging machine

Accident Summary Nr: 126411.015 -- Report ID: 0626300 -- Event Date: 05/18/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1476302.01505/26/2020424410Marley Spoon Inc.

Abstract: At 9:00 a.m. on May 18, 2020, an employee was working for a firm that prepared and delivered recipes and ingredients that the recipients cooked at home. She worked as a machine operator. She was operating the firm's Guangzhou Fuluke Machinery Co. model 500KG sauce repack machine. The machine mixed sauces and packaged them in quantities for inclusion in the meals it sent out. A package had jammed in the machine. The machine was still energized. It had three sources of energy: electrical energy (220 volts), pneumatic energy (100 psi), and the residual mechanical energy of the cutting and mixing blades after electrical energy had been turned off. The employee reached below the barrier guard to pull out the jammed package. Her left thumb became caught by a moving part. It was amputated. The employee was treated without hospitalization. The machine was not completely guarded, later measurements showed. The guarding for the point of operation was inadequate. The plastic adjustable guarding was not enclosed at the top and bottom, allowing employees to routinely bypass the plastic barrier guarding that was in place. As part of routine production, employees had to bypass the guard, because the food packaging cutters would not reach the plastic container as the packaging was cut. The employer provided employees with spatulas to reach under the plastic barrier guards to ensure that production continued. This occurred multiple times in a shift. On May 14, 2019, another employee had a similar incident on the firm's powder and paste repacking machine. In that incident, an employee bypassed the inadequate machine guarding at the top and bottom of the adjustable plastic guard.

Keywords: Amputated, Amputation, Blade, Caught By, Clearing, Cutting, Food Delivery Service, Food processing, Food service, Hand Tool, Instantaneous amputation, Jammed, Lockout, Lockout/Tagout, Machine Cycled, Machine Guarding, Misjudgment, Misjudgment of Hazardous Situation, Reach, Reaching, Thumb, Training, Traumatic Amputation, Unguarded, Work Rules

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1476302.015 42 M Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.