Accident Summary Nr: 125943.015 - Two employees sustain multiple injuries when scissor lift is

Accident Summary Nr: 125943.015 -- Report ID: 0627700 -- Event Date: 09/06/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1430243.01509/09/2019332410Axh Air-Coolers, Llc

Abstract: At 7:30 a.m. on September 6, 2019, two employees were conducting maintenance on an overhead bridge crane from an extended scissor lift, elevated 24 feet above a concrete work floor. The scissor lift was struck by a crane load. The scissor lift toppled over on the concrete floor. The employee sustained fractures, back injuries, and contusions. Both employees were hospitalized.

Keywords: Back, Bridge, Contusion, Crane, Crane Load, Fall From Elevation, Fracture, Maintenance, Scissor lift, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1430243.015 35 M Hospitalized injury
2 1430243.015 35 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.