Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 124614.015 - Employee lacerates liver when struck by tree being felled

Accident Summary Nr: 124614.015 -- Report ID: 0950612 -- Event Date: 02/27/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1467946.01503/05/2020561730Davey Tree Surgery Company

Abstract: At 1:50 p.m. on February 27, 2020, an employee was working as a foreman for a tree care contractor felling a 13-inch in diameter tree in a remote, wooded area. The crew proceeded to take down the tree without cutting a hinge or securing the tree with a rope. As a result, the falling tree struck the employee, lacerating his liver and requiring hospitalization.

Keywords: Blunt force, Blunt force trauma, Chain Saw, Clearing, Cutting, Falling Object, Flying Object, Laceration, Liver, Misjudgment, Misjudgment of Hazardous Situation, Rope, Struck By, Supervisor, Tree, Tree Felling, Unsecured, Unstable Position

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1467946.015 27 M Hospitalized injury Chainsaw Operator

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.