Accident Summary Nr: 124351.015 - Two employees are injured in fall from lift

Accident Summary Nr: 124351.015 -- Report ID: 0950635 -- Event Date: 08/28/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1429152.01509/05/2019562910Sensitive Environment

Abstract: At 11:45 p.m. on August 28, 2019, two employees were working on a scissor lift extended approximately fifteen in the air to access the spindle of a manual rolling door of a warehouse to remove it. The forks of a forklift were raised to the bottom of the spindle so that it could be lowered by the forks and not free fall to the ground. The employees secured the spindle to the forks with a heavy chain however, as the employees were removing the last bolt, they had to remove the chain to access the bolt. The employees did not replace the chain as the bolt was removed. As Employee #1 removed the bolt with a tile bar, the spindle came off the wall with enough force to bounce off the forks and the wall before hitting the ground and striking the scissor lift. The spindle knocked the scissor lift to the asphalt with the employees on it. Emergency services were notified, arrived on site, stabilized the employees and transported them to a local medical center. Employee #1 was treated for broken ribs and a broken back and underwent surgery for the injury to his back and was released from the hospital on September 6, 2019. Employee #2 was treated and underwent surgery for a broken foot.

Keywords: Back, Blunt force, Blunt force trauma, Bolt, Chain, Elevated Work Platform, Fall, Fall From Elevation, Falling Object, Foot, Forklift, Forks, Fracture, Lift, Overhead Door, Removing, Rib, Scissor lift, Spindle, Struck Against, Tips Over

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1429152.015 56 M Hospitalized injury Laborers, except construction
2 1429152.015 56 M Hospitalized injury Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.