Accident Report Detail
Accident Summary Nr: 124086.015 - Employee sustains blunt force trauma when struck by vise
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1463511.015 | 09/10/2019 | 3728 | 336413 | 317725425 - The Boeing Co |
Abstract: At 10:45 a.m. on September 7, 2019, an employee was using a Cincinnati Horizontal Universal Milling Machine to square up raw material in the skills lab. An Iscar 5 inch face mill-cutting tool caught the aluminum block work piece and shifted the material in a Kurt 8 inch vise, model #0810-000927. One of the two tie down bolts on the vise sheared off, causing the vise to come loose and travel through the guard, striking the employee. The employee suffered blunt force injuries to her chest and abdomen and was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1463511.015 | 27 | M | Hospitalized injury | Machinist apprentices |
Translate